Incoherent dedispersion works on the channelized filterbank: each frequency channel is shifted in time by the predicted 1/f^2 delay and the channels are summed. It is fast and cheap, but because each channel still has finite width, the chirp is only corrected to within one channel, leaving residual smearing that broadens the pulse. Coherent dedispersion instead convolves the raw voltage data with the inverse of the dispersion filter before channelization, removing the intra-channel smearing and preserving the full time resolution of the observation. Coherent dedispersion is used when the dispersion measure is large or the observing bandwidth is wide enough that incoherent smearing would destroy the pulse shape.
Detecting and Studying Pulsars: Core Methods and Instruments
From Telescope Data to Candidate: Dedispersion, Folding, and Search Pipelines
Two Ways to Undo the Chirp
2 / 5
So how do you undo a chirp that was imposed light-years away? There are two answers, and the difference between them decides how sharp your pulse will be. The first is incoherent dedispersion: take the channelized data, shift each frequency channel by the delay the 1 over f squared law predicts, then add the channels together.